2015年2月27日星期五

Properties of titanium pump

1)10-8 PA pressure limit

(2) the pumping speed,
titanium pump pumping speed and the anode voltage and magnetic field intensity, magnetic field strength when the pumping speed is high, the anode voltage corresponding to the best pumping speed is high.

  Commonly used titanium pump pumping speed of 25 L / s, 5 liters / sec. Require large pumping speed for the occasion, the basic structural unit can be used in parallel manner to make the pumping speed 50 L / s, 100 liters / sec etc..

(3) start pressure, 10-2 pa
(4) life,
  •  cathode depletion of life
Plate due to sputtering cathode penetrating and the pump can not be used.
  •  anodic stripping life
Anodic Deposition of titanium film thickness is too large will have peeled off, resulting in irregular titanium alloy pump pressure is intense change, the pump can not be used.
  •  anode sucking the life
The anode of adsorbed and dissolved a lot of helium, hydrogen, when the saturated adsorption gas when the pump can not.

  Under normal circumstances, life of up to tens of thousands of hours of sputtering ion pump.

2015年2月24日星期二

Titanium pump gas removal mechanism

1) on the activity of gas exhausting

Chemical adsorption excluded depends mainly on the deposited on the anode cylinder wall titanium membrane for N2, O2, CO and CO2 gases.


2) of the hydrogen pumping

The hydrogen titanium pumps chemical adsorption, diffusion, absorption, or dissolution.


3) on the inert gas exhausting

Exclusion of inert gases, mainly by ion buried, by inert gas ion bombardment ionization of the cathode, the following three conditions,
  • Ion directly into the cathode, anode plate or into the cathode edge on the opposite side of the titanium  deposition in.
  • Oblique ion cut into the surface of the cathode, with ion and titanium was blown off and deposited on the cathode plates or other places around.
  • Ion did not enter the plate, but receive electronic and composite for neutral atoms from.the cathode, and then reflected to the inner surface of the titanium anode film.

2015年2月21日星期六

The secondary electrons of titanium plate

Ion bombardment of titanium plates can be hit two times, electronic, electromagnetic field into the rotating electron clouds two times by electronic, electronic supplement lost.

  Each of the gas molecules are ionized at the same time, at least let a electronic, these electronic also enters the rotating electron cloud, they and the two electronic together compensation electron loss went to the anode and, thus can continue to maintain Pan Ning discharge.

2015年2月18日星期三

Inspiratory capacity of titanium film

Sputtered titanium  atoms deposited on the inner wall, the anode and cathode plate pumping ability, forming a titanium film fresh maintaining titanium pump. Sputtering ion with the incident ion energy, mass and incident angle is different, high energy, sputtering ion mass is big. The oblique better effect than vertical bombardment.

  In order to ensure that the suction capacity of titanium film on the anode cylinder, must ensure enough sputtering rate, that is required to have enough voltage, to ensure that the ion energy bombarding get enough.


2015年2月15日星期日

Ion bombardment of titanium plate

Gas molecules and electron impact ionization and is rotating, gas ions under the action of the electric field, fly and the bombardment of the cathode titanium plate.

Two effects of titanium plates ion bombardment,
1, the formation of sputtered titanium pump, titanium film.
2, hit two times electron.


2015年2月12日星期四

Pan Ning discharge,titanium pump

When the anode voltage is high, in order to avoid electronic fall to the anode, must add a strong axial magnetic field. In the axial direction, central section movement when the electronic anode cylinder, accelerated by the effect of electric field force, the electron velocity is larger and larger, across the central section, the electric force impede the electron do decelerated motion, close to the cathode plate Vz decay to zero, the electron acceleration by electric field force and the effect of re the reverse acceleration movement, and started to decelerate over center section, repeat the above exercise so don't stop.

  Electrons in the anode tube in after a long journey to fall on the anode. A large number of electronic magnetic field constraints to wheel line form close to the anode cylinder rotation, the formation of a layer of electron cloud. The rotation frequency rotating electron cloud is about 100MHz, the electron density of up to 1010 (A / cm 3) order. The phenomenon known as the Pan Ning discharge.

2015年2月9日星期一

Titanium pump working principle

The motion of the electron in the titanium pump anode tube in axial velocity component, Vz and radial velocity Vr, because Vr and axial magnetic field Bz perpendicular, electron by the Lorentz force F=eVr´ Bz effect, so the electrons to the anode tube in addition to the action of electric field force is axial symmetry, but also by the Lorentz force Bz, the electron motion into linear motion and axial cross section on thewheel rolling line movement. 

   In cross section of electricity Sub wheel rolling line moving radius size is a function of the electron velocity and magnetic fieldstrength, the larger the electronic speed (the anode voltage is higher), round the ring rolling line larger; magnetic field stronger, wheel rolling line of the circle is smaller.

2015年2月6日星期五

The structure of titanium pump

Titanium pump can be divided into two types and the three pole type, triode type may increase the argon (Ar) pumping speed. Structure of dipolar type titanium pump
   The anode A, composed of a plurality of 0.1~0.3mm thick stainless steel thin-wall cylinder, the composition of 12~40mm in diameter, anode ends with a K thick 1~3mm titanium cathode.
   Axis and perpendicular to the surface of cathode and anode cylinder, voltage and 3~7KV between the two, the uniform axial magnetic field and 1000~3000 Gauss of the anode cylinder.

2015年2月2日星期一

The economy of the titanium pump

Titanium pump, is in equipment manufacturing material, with the use of titanium and titanium alloy corrosion, the proportion of small, high strength, good comprehensivemechanical performance at high and low temperature characteristics, flow in the impeller components, and packing seal used in the manufacture of integrated node of titanium or titanium alloy.

  Titanium pump with excellent corrosion resistance, resistant to most organic acid,inorganic acid, organic compound, alkali, salt solution corrosion, and is suitable for conveying solid particles, easy crystal medium, especially for long period operation,improve economy.

  To overcome the insufficiency of packing and mechanical seals, has the advantages of simple operation, reliable sealing structure, can fundamentally solve the packing seal sleeve, packing is easy to wear problems.

  At present, the titanium pumps are widely used in alkali, salt making, metallurgical and mining and petroleum chemical engineering.